Handover inspection in Gables

Your full list, written before practical completion and the final payment.

  • About two weeks before your handover date
  • 2 to 3 hours on site
  • Report within 24 hours
Request your quoteLeave your details and an inspector rings you back.

No obligation. We use your details for your quote and may contact you about it even if you don't finish.

Fully licensed & accredited

Stage7 of 7
When to bookAbout two weeks before your handover date
Time on site2 to 3 hours on site
Inspected againstThe Guide to Standards and Tolerances 2017, the NCC, your contract drawings and inclusions

What is included in a Gables pre-handover (PCI) inspection

  • Weep holes present and unblocked
  • Control and articulation joints
  • Balcony overflow and floor waste
  • Balcony tiles fully bedded
  • Capping falls and fixing
  • First floor window restrictors
  • Water stop at the laundry
  • Ground falling away from walls
  • Cladding clear of soil
  • Isolation joints to paths and drives
  • Paint, plaster and trims in daylight
  • Doors, drawers and hardware
  • Wet area grout and silicone
  • Roof viewed by drone
Why it matters here

Pre-handover (PCI) inspections on Gables builds

Gables handovers are where facade and balcony items surface together. Weep holes missing or too far apart, joints rendered over or left out where the brickwork steps, balcony tiles on dabs, a membrane that never reached the overflow, cappings with water lying on them. Inside, an upstairs bedroom window without a restrictor and a laundry without a water stop.

What we find at this stage in Gables

  • Weep holes missing or over 1200mm apart
  • Joints rendered over or omitted
  • Balcony tiles spot-fixed
  • Membrane not into the overflow
  • Missing first floor window restrictor
Obstructed weep holes still present when the house was rechecked, found during a handover inspection in Gables
Obstructed weep holes still present when the house was rechecked
Sample findings

Sample defects found during our pre-handover (PCI) inspections in Gables

Annotated findings from Pre-handover (PCI) inspections.

Weep holes missing from a second rendered wall, trapping moisture in the cavity, found during a handover inspection in Gables
Weep holes missing from a second rendered wall, trapping moisture in the cavity
Balcony floor tiles spot-fixed rather than fully bedded, so they can crack, found during a handover inspection in Gables
Balcony floor tiles spot-fixed rather than fully bedded, so they can crack
Expansion joint shown on the plans but missing from the finished wall, found during a handover inspection in Gables
Expansion joint shown on the plans but missing from the finished wall
Stains and ponding on a capping that will corrode it over time, found during a handover inspection in Gables
Stains and ponding on a capping that will corrode it over time

The other stages of a Gables build

  1. Bored piers inspection in Gables1Bored piersOnce the piers are bored, before any concrete arrives
  2. Slab pre-pour inspection in Gables2Slab pre-pourThe day before the pour, once steel and pods are set
  3. Frame inspection in Gables3FrameFrame and trusses standing, roof cover on, before sarking and linings
  4. Lock-up (pre-plaster) inspection in Gables4Lock-up (pre-plaster)Roof, cladding, windows and rough-in done, before plaster
  5. Fixing inspection in Gables5FixingJoinery, doors and trims in, before the painter starts
  6. Waterproofing inspection in Gables6WaterproofingMembrane cured, before the tiler arrives

All construction stage inspections in Gables →

Guides

Construction stage guides for Gables

All guides →

Book a pre-handover (pci) inspection in Gables

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Pre-handover (PCI) inspections in Gables: common questions

How many hours does a Gables handover visit run?

Two to three hours, longer on a large double storey.

What is a window restrictor?

A device limiting how far an upstairs window opens, so a child cannot fall through. The opening limit is 125mm where the rule applies.

Why check weep hole spacing?

Too few weep holes leaves water in the cavity. Spacing over 1200mm was recorded on a Gables home this year.

Is the Gables roof itself looked at?

We view it by drone or from a ladder where safe, and enter the roof space where accessible.

Will you return to Gables once the repairs are done?

Yes. A recheck marks each item fixed, partly fixed or still open.

Ought I to sign off before reading the Gables report?

Ideally not. Your report is the leverage while the final payment is outstanding.